kWh Analytics, a local weather insurance coverage supplier, has launched its sixth annual Solar Risk Assessment report, which gives a data-driven overview of the dangers of photo voltaic property. . The report contains contributions from photo voltaic trade leaders in know-how, financing, and insurance coverage.

“To obtain renewable vitality deployment targets, the main target have to be on good progress – counting on knowledge to tell selections and utilizing resilience measures to guard property,” stated the kWh Analytics chief govt. officer Jason Kaminsky.

The report identifies 14 dangers that the photo voltaic trade wants to pay attention to, together with dangers associated to excessive climate and operational dangers. For the primary time this yr, the dangers related to battery vitality storage are included. This information covers extreme climate hazards, with subsequent articles reviewing operational and storage-related hazards.

Find protection for weather-related dangers in photo voltaic property HERE. This report will give attention to photo voltaic asset operational dangers, with the subsequent article specializing in vitality storage threat evaluation.

Aggregating portfolios of 4 or extra tasks cuts out excessive threat situations

kWh Analytics discovered a pattern that the majority monetary forecasts underestimate the chance of utmost draw back situations, generally known as P99 degree occasions. These occasions are anticipated to happen as soon as each 100 years, however the firm’s knowledge reveals that catastrophic injury P99 occasions happen as usually as each 6 years.

“One attainable option to cut back the chance of extreme draw back situations is to pool portfolios of tasks for financing – threat distribution will increase the likelihood {that a} dangerous efficiency web site might be balanced with a greater portfolio,” stated kWh Analytics.

The firm discovered that the median efficiency of all 301 utility-scale photo voltaic websites, masking 935 years of manufacturing for 2017 to 2022. It discovered that by aggregating a minimum of 4 tasks into in a portfolio, the chance of all property that make lower than 80% of the preliminary forecasts is to be reduce in half.

However, kWh Analytics says the good thing about portfolio aggregation pales compared to utilizing extra correct manufacturing and threat forecasts. It stated that bettering P50 forecast accuracy with life like, data-driven availability estimates has the potential to cut back the prevalence of utmost draw back situations by as much as an element of 10.

Image kWh Analytics

Voltage collapse can cut back manufacturing by greater than 20%

Voltage breakdown is a major discount in voltage degree inside the DC area. Solarlytics says voltage breakdown is a quickly rising downside in photo voltaic properties.

“As the voltage collapses beneath the inverter’s working vary, it blocks the inverter’s skill to match the DC area voltage, leading to vitality loss. In superior instances, the collapse causes the inverters are always tripping, which results in vitality losses exceeding 20%,” stated Solarlytics.

Voltage collapse could be attributable to varied causes. For instance, tasks designed for chilly climate climates require shorter cords to carry out on chilly days. If these techniques face hotter summer time climate, the string voltage might drop beneath the inverter’s vary.

Solarlytics estimates that greater than 30% of all utility-scale photo voltaic vegetation endure voltage breakdowns. The firm recommends using superior string degree monitoring and optimization, correct sizing and configuration of the inverter, and steady monitoring for early detection of voltage sags to make corrective motion.

Operations and upkeep corrective actions on the rise

Solar Advanced Analytics, Univers discovered that operations and upkeep (O&M) corrective actions proceed to extend as extra photo voltaic property come on-line. This previous winter, the corporate discovered a 14% enhance in corrective actions taken in comparison with summer time 2023. It analyzed knowledge from greater than 11 GW of property at greater than 300 websites .

It discovered that fifty% of corrective actions had been attributed to the well being of DC-level system parts. This is adopted by inverter corrective actions and repairs, which characterize 15% of all corrective actions. Data availability actions ranked third, representing 13% of the actions taken.

About 43% of DC corrective actions happen throughout winter, stated Solar Advanced Analytics, which reveals the affect of winter circumstances equivalent to low temperatures, diminished irradiance, and snow cowl on DC inputs and strings. On the opposite, inverters act rapidly to appropriate in hotter intervals, as a result of the excessive temperature of the system can result in the failure of cooling the system and decreasing the effectivity of the inverter.

Seasonal variations spotlight the necessity for O&M operators to be strategic seasonally, planning for DC points within the winter and inverter points in the summertime. By concentrating on O&M schedules, suppliers can restrict truck rolls and correctly allocate stock and workforce assets.

Safety issues required partial or complete de-energization in 11% of audited techniques

SolarGrade discovered that important points had been present in 11% of US photo voltaic tasks in a sequence of inspections performed from January 2023 to March 2024. This important degree designation is positioned on property that’s more likely to have catastrophic failure earlier than the subsequent upkeep exercise.

About 11% of US photo voltaic property analyzed had been discovered to have important points that required the system to be partially or utterly de-energized till the issue was resolved.

The commonest important concern by a big margin is issues with PV connectors, that are the reason for 46% of tasks requiring de-energization. Unsafe connectors are sometimes resulting from advanced set up and cooling necessities, widespread myths about MC4 compatibility, and a scarcity of area coaching, says SolarGrade. The firm gives a photo voltaic connector security information.

Uncontrolled air pollution can cut back annual manufacturing by as much as 50%

Soiling is the buildup of mud, grime, and particulates on the photo voltaic panel. According to knowledge from the National Renewable Energy Laboratory, polluting can inflicting as much as 50% manufacturing loss in areas vulnerable to air pollution.

Clean Power Research gives a mannequin to know regional variations for air pollution threat, which fluctuate primarily based on location. The threat is especially excessive in areas with low annual rainfall totals, which emphasizes the necessity for usually scheduled soil cleansing in these areas.

“By utilizing a wide range of floor loss fashions, mixed with correct mannequin inputs and dependable irradiance knowledge from SolarAnywhere, trade consultants can develop efficient methods to reduce efficiency uncertainty when mannequin PV techniques in advanced local weather circumstances,” says Clean Power Research.

Inverters account for 59% of misplaced vitality

While PV techniques are designed to final 35 years or extra, varied parts fail sooner. An evaluation of the O&M logs revealed that essentially the most frequent reason for corrective upkeep points in response to a major loss is because of inverters (51%). This is adopted by the upkeep of DC distribution tools, together with connectors, combiners, and wiring, which represents 21% of the actions carried out.

kWh Analytics discovered that inverter failures trigger the best time-to-resolution and result in the best misplaced vitality, about 59% of misplaced vitality resulting from corrective actions. The commonest inverter O&M tickets are associated to controller, fan, and logic board points. This knowledge could be helpful in figuring out buying priorities for spare elements, says kWh Analytics.

Image: kWh Analytics

The upcoming third article on kWh Analytics Solar Risk Assessment will give attention to battery vitality storage techniques operational dangers, marking the primary time that storage is included in its annual report. For extra information on vitality saving, see pv journal new Energy Conservation News web site.

This content material is protected by copyright and is probably not reused. If you need to cooperate with us and need to reuse a few of our content material, please contact: [email protected].



Source link

LEAVE A REPLY

Please enter your comment!
Please enter your name here

FOLLOW US

0FansLike
0FollowersFollow
0SubscribersSubscribe
spot_img

Related Stories