PV string fault detection method primarily based on multi-layer neural community – pv journal International


Indian scientists have proposed using a multilayer neural community to detect line-to-ground, line-to-line, and bypass diode faults in PV module strings. They examined the brand new methodology on a 22.5 kW photo voltaic array and reportedly achieved “aggressive” accuracy outcomes.

A bunch of researchers from India has proposed a novel PV string fault detection method for PV strings that makes use of a multi-layer neural community (MLNN), a machine-learning method that may deal with complicated relationships by study their hierarchical illustration.

“Line-to-ground (LG) and line-to-line (LL) faults are detected, labeled, and localized with the assistance of the proposed method,” stated the teachers. “The proposed MLNN method requires just one present sensor to be put in for every thread. However, it may possibly establish issues in photovoltaic arrays of any dimension or diploma of mismatch.

The analysis staff skilled the error detection method on quite a lot of knowledge with completely different environmental situations. It takes into consideration parameters equivalent to temperature, irradiance, and most energy.

“In the case of nonlinear classification issues, multi-class deep neural networks are carried out within the extraction course of,” the teachers defined. “The multi-layer perceptron is beneath nonlinear association, ie, the nonlinear complicated knowledge is suitable for the computation course of. Each layer is related to hidden items. Each hidden unit processes weights with the assistance of operate on the bias.

To check the MLNN detection methodology for PV string faults, the researchers simulated a 22.5 kW photo voltaic array consisting of 4 parallel strings and 10-series modules. In the simulation, they obtained data on when the present dropped to zero and the present variations within the higher and decrease modules of every wire. Those steps are processed with errors and variations and in contrast to what’s introduced within the detection mannequin.

The researchers outlined accuracy as “the fraction of the entire variety of correct predictions made by the potential outputs, divided by the entire variety of predictions made by the matrix.”

The proposed MLNN is reported to realize an accuracy of 98.76% for the detection of LL faults, LG faults, and bypass diode faults. This compares to an accuracy of 96.5% achieved by the probabilistic neural community (PNN), 92.1% by the radial foundation features (RBF), and 90% by the convolutional neural community (CNN), cited in earlier scientific literature.

“The proposed MLNN method can resolve any nonlinear complicated computations, deal with massive enter error panel knowledge, and rapidly predict the error,” the researchers concluded.

Their findings are introduced in “Photovoltaic string fault optimization utilizing a multi-layer neural community method,” revealed of Engineering Results. The analysis staff consists of lecturers from the Marri Laxman Reddy Institute of Technology and Management, the National Institute of Technology Andhra Pradesh, and the CVR College of Engineering.